隨著經(jīng)濟(jì)的發(fā)展,地下鐵道工程由原來的地下隧道,發(fā)展為地上和地下的城市軌道交通,其制式也多樣化,本標(biāo)準(zhǔn)除不適用于“磁懸浮”“跨坐式”“直線電機(jī)”制式城市軌道交通外,也適用于其他制式的城市輕型軌道交通的施工。
本標(biāo)準(zhǔn)規(guī)定了建筑工人安全操作的術(shù)語和定義、總則、一般規(guī)定、架子工、瓦工、抹灰工、石工、木工、鋼筋工、混凝土工、普通工、電工、安裝電工、防水工、起重吊裝工、金屬焊割作業(yè)工、油漆工、測量工、機(jī)械設(shè)備維修工、水暖工、鉚工、通風(fēng)工、筑爐工、保溫工、樁基施工、大模片施工、鋼結(jié)構(gòu)及網(wǎng)架施工、裝飾裝修施工、拆除施工、土方及筑路機(jī)械、樁工機(jī)械、吊裝及垂直運(yùn)輸機(jī)械、混凝土機(jī)械、中小型施工機(jī)具、市政工程的操作。
1.1 This specification covers concentric-lay-stranded conductors made from round aluminum 1350-H19 (extra hard) wires and round, coated steel core wire(s) for use as overhead electrical conductors (Explanatory Note 1 and Explanatory Note 2).1.2 ACSR covered by this specification has nine types of coated steel core wire which are designated by abbreviations as follows (Explanatory Note 2):1.2.1 ACSR/GA-ACSR using Class A zinc-coated steel wire,1.2.2 ACSR/GB-ACSR using Class B zinc-coated steel wire,1.2.3 ACSR/GC-ACSR using Class C zinc-coated steel wire,1.2.4 ACSR/MA-ACSR using Class A Zn-5A1-MM coated steel wire,1.2.5 ACSR/MB-ACSR using Class B Zn-5A1-MM coated steel wire,1.2.6 ACSR/MC-ACSR using Class C Zn-5A1-MM coated steel wire,1.2.7 ACSR/HS-ACSR using Class A zinc-coated high-strength steel wires,1.2.8 ACSR/MS-ACSR using Class A Zn-5A1-MM coated high-strength steel wires, and 1.2.9 ACSR/AZ-ACSR using aluminum-coated (aluminized) steel wire.1.3 The values stated in inch-pound or SI units are to be regarded separately as standard. The values in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.1.3.1 For density, resistivity and temperature, the values stated in SI units are to be regarded as standard.Note 18212;The aluminum and temper designations conform to ANSI Standard H35.1/H35.1M; Aluminum 1350 corresponds to UNS No. A91350 in accordance with Practice E527.
This European Standard specifies the electrical and mechanical characteristics of ACSS conductors madeof round or formed annealed aluminium wires and steel wires stranded in alternate directions, made ofone or a combination of any of the following.
This International Standard specifies the electrical and mechanical characteristics ofconcentric lay stranded overhead electrical conductors, containing one or more selfsupportingaluminium or aluminium alloy layer(s) as depicted in Figure 1, made ofcombinations of any of the following metal wires:a) hard-drawn aluminium as per IEC 60889, designated A1;b) aluminium alloy type A or B as per IEC 60104, designated A2 or A3;c) thermal resistant aluminium alloy type as per IEC 62004, designated AT1, AT2, AT3 orAT4;d) regular strength steel as per IEC 60888, designated S1A or S1B;e) high strength steel as per IEC 60888, designated S2A or S2B;f) extra-high strength steel as per IEC 60888, designated S3A;g) aluminium-clad steel as per IEC 61232, designated 20SA, 27SA, 30SA or 40SA.NOTE This standard covers the construction of self-damping conductors, as well as gap-type conductors.Although both types of conductors share a common design feature and the presence of one or more gaps betweenlayers, they are intended for different purposes. Self-damping conductors (SDC) may have more than one gap toprovide increased self-damping, whereas gap-type conductors are so designed as to allow the aluminium layers toslide freely over the core during installation, and therefore usually do not require more than one gap.